Automatic data logging: 500 reports
Operating Range: Up to 160mm
Data input for fitting code:
Bar code scanner
Welding monitoring system:
Welding voltage, resistance, welding current,established
contact, short circuit, ambient temperature,input frequency,
input voltage, memory control, systemtemperature, heater
coil error, emergency off, computer-assisted maintenance
Standard-compliant ISO 12176 traceability:
Project/commission number 32 alphanumeric
characters, ISO-compliant welder ID code, 1st
additional (user-defined) data 20 alphanumeric
characters, 2nd additional (user-defined) data 15
alphanumeric characters
Data download with output menu:
USB interface port (USB A) for data transfer as
PDF abstract or extended report to USB stick or
to label tag printer, incl. dedicated printing menu;
transfer also possible in the HRNER DataWork
format; using a powerful download menu to select
date range, commission number or report number
range, or all reports
Display screen:
LED screen 2 lines with 20alphanumeric
characters each, character size 5mm
Output voltage:8 V - 48 V
Output current:max. 65 A
Input voltage:180 V - 280 V (230 V)
Input frequency:40 Hz - 70 Hz
Rated input current:AC 8 A
Approvals, quality, ingress protection:
CE, ISO 9001:2008, IP54 (IP64 optional)
Language:DE, EN, FR, BG, CS, ZH, NL, FI, GR,
IT, NO, RO,SK, TR, RU,
others uponrequest
Temperature range:-20 C to +60 C
Power cord:5 m with Euro plug
Welding cable:3.2 m with 4.0 mmconnection
terminals
Weight:8.1 kg
Dimensions:W 210 x H 235 x D 225 mm
Accessories: user's manual
DE, EN, FR
Manufacturer warranty: 12 months ( Physical damage& Electrical damage is not cover in Warranty case)
Part number: 301-000-000
NAY ENTERPRISE